ID: 8933 Title: Performance of dual layer micro MLC versus standard single layer MLC for IMRT delivery Purpose To evaluate the performance characteristics of a first-of-its-kind dual layer micro multi-leaf collimator (DmMLC) and compare it dosimetrically with standard, single layer MLCs for use in intensity modulated radiation therapy (IMRT). Method and Materials The DmMLC performance was studi...

2015
Shifeng Chen Byong Yong Yi Xiaocheng Yang Huijun Xu Karl L. Prado Warren D. D'Souza

Unlike other commercial treatment planning systems (TPS) which model the rounded leaf end differently (such as the MLC dosimetric leaf gap (DLG) or rounded leaf-tip radius), the RayStation TPS (RaySearch Laboratories, Stockholm, Sweden) models transmission through the rounded leaf end of the MLC with a step function, in which the radiation transmission through the leaf end is the square root of...

A Mostaar Gh Geraily, R Mohammadi S A Rohani S R Mahdavi, S Ueltzhöffer

Background: Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process.Objective: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films.Material and Methods: Leaf Position accur...

Journal: :Medical physics 2003
J E Bayouth S M Morrill

The objective of this work was to measure the performance characteristics of a double-focus multileaf collimator (MLC) for intensity modulated radiation therapy (IMRT), specifically the variation in penumbra and leakage for narrow fields as a function of field position over a 20x27 cm space available for segmented MLC IMRT. Measurements were made with 6 MV x rays through a MLC containing 29 lea...

2008
Yaxi Liu Chengyu Shi Patricia Tynan Niko Papanikolaou

The purpose of the present work was to measure the performance characteristics in the penumbra region and on the leaf-end of an innovative dual-layer micro multileaf collimator (DmMLC). The DmMLC consists of two orthogonal (upper and lower) layers of leaves; a standard MLC consists of one layer. The DmMLC provides unique performance characteristics in smoothing dose undulation, reducing leaf-en...

2008
Olivia Amanda García‐Garduño Miguel Ángel Celis José Manuel Lárraga‐Gutiérrez Sergio Moreno‐Jiménez Arnulfo Martínez‐Dávalos Mercedes Rodríguez‐Villafuerte

Micro-multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation sys...

2017
Nick Petersen David Perrin Wayne Newhauser Rui Zhang

The purpose of this study was to evaluate the impact of selected configuration parameters that govern multileaf collimator (MLC) transmission and rounded leaf offset in a commercial treatment planning system (TPS) (Pinnacle3, Philips Medical Systems, Andover, MA, USA) on the accuracy of intensity-modulated radiation therapy (IMRT) dose calculation. The MLC leaf transmission factor was modified ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعت آب و برق (شهید عباسپور) - دانشکده مهندسی برق و کامپیوتر 1392

abstract according to increase in electricity consumption in one hand and power systemsreliability importance in another , fault location detection techniqueshave beenrecentlytaken to consideration. an algorithm based on collected data from both transmission line endsproposed in this thesis. in order to reducecapacitance effects of transmission line, distributed parametersof transmission line...

Journal: :Journal of Computer and System Sciences 1998

Journal: :Medical physics 2000
M R Arnfield J V Siebers J O Kim Q Wu P J Keall R Mohan

The main purpose of this work is to demonstrate a practical means of determining the leaf transmission and scatter characteristics of a multileaf collimator (MLC) pertinent to the commissioning of dynamic intensity modulated radiotherapy, especially for the sweeping window technique. The data are necessary for the conversion of intensity distributions produced by intensity-modulated radiotherap...